INSTALLATION
PROCEDURE
1. INSTALL COOLING FAN MOTOR RH
(a) Cooling Fan Motor 100 W Type:
(1) Install the cooling fan motor RH with the 3 screws.
Torque:
2.6 N·m {27 kgf·cm, 23 in·lbf}
(2) Engage the 3 clamps.
(3) Connect the cooling fan motor RH connector.
(b) Cooling Fan Motor 200 W Type:
(1) Install the cooling fan motor RH with the 3 screws.
Torque:
3.9 N·m {40 kgf·cm, 35 in·lbf}
(2) Engage the 2 clamps.
(3) Connect the cooling fan motor RH connector.
2. INSTALL COOLING FAN MOTOR LH
(a) Install the cooling fan motor LH with the 3 screws.
Torque:
3.9 N·m {40 kgf·cm, 35 in·lbf}
(b) Engage the 3 clamps.
(c) Connect the cooling fan motor LH connector.
3. INSTALL FAN RH
NOTICE:
Do not reverse the position of the fan LH and fan RH when installing them. Doing so may damage the parts.
(a) Install the fan RH with the nut.
Torque:
6.3 N·m {64 kgf·cm, 56 in·lbf}
4. INSTALL FAN LH
NOTICE:
Do not reverse the position of the fan LH and fan RH when installing them. Doing so may damage the parts.
(a) Install the fan LH with the nut.
Torque:
6.3 N·m {64 kgf·cm, 56 in·lbf}
5. INSTALL RADIATOR ASSEMBLY
Click here
Lexus RX (RX 350L, RX450h) 2016-2024 Repair Manual > Lin Communication System: Dtc Check / Clear
DTC CHECK / CLEAR CHECK DTC (a) Connect the Techstream to the DLC3. (b) Turn the engine switch on (IG). (c) Turn the Techstream on. (d) Enter the following menus: Body Electrical / Main Body or Smart Access / Trouble Codes. Body Electrical > Main Body > Trouble Codes Body Electrical > Smart ...
Lexus RX (RX 350L, RX450h) 2016-2024 Repair Manual > Sfi System: Control Module Performance Bank 2 Component Internal Failure (P060596,P060796)
MONITOR DESCRIPTION The ECM continuously monitors its internal processors (CPUs) and heated oxygen sensor transistors. This self-check ensures that the ECM is functioning properly. DTC No. Detection Item DTC Detection Condition Trouble Area MIL Memory Note P060596 Control Module ...