INSPECTION
PROCEDURE
1. INSPECT NO. 2 VACUUM SWITCHING VALVE ASSEMBLY
(a) Measure the resistance.
(1) Measure the resistance according to the value(s) in the table below. Standard Resistance:
If the result is not as specified, replace the No. 2 vacuum switching valve assembly. |
|
*a | Port (E) |
*b | Port (F) |
*c | Air |
*d | Filter |
(b) Check the operation of the No. 2 vacuum switching valve assembly.
(1) Using a vacuum pump, check that air flows from port (E) to the filter.
Standard:
Condition | Standard |
---|---|
Vacuum of 67 kPa (503 mmHg, 19.8 in.Hg) applied to port (F) | Air flows from port (E) to the filter. |
If the result is not as specified, replace the No. 2 vacuum switching valve assembly.
(2) Apply battery voltage to the terminals and check that air flows from port (E) to port (F). Standard:
If the result is not as specified, replace the No. 2 vacuum switching valve assembly. |
|
Lexus RX (RX 350L, RX450h) 2016-2024 Repair Manual > Fuel Lid Opener Unit: Installation
INSTALLATION PROCEDURE 1. INSTALL FUEL FILLER OPENING LID SUB-ASSEMBLY (a) Temporarily install the fuel tank filler pipe shield with the drain hole and cutout facing downward as shown in the illustration. *a Rib *b Drain Hole *c Cutout (b) Install the fuel inle ...
Lexus RX (RX 350L, RX450h) 2016-2024 Repair Manual > Exhaust Manifold: Installation
INSTALLATION PROCEDURE 1. INSTALL STUD BOLT HINT: If a stud bolt is deformed or its threads are damaged, replace it. (a) Using an E8 "TORX" socket wrench, install the 2 stud bolts to the exhaust manifold (TWC: Front Catalyst). Torque: 19.5 N·m {199 kgf·cm, 14 ft·lbf} (b) Using ...