TERMINALS OF ECU
STEERING WHEEL HEATER CONTROL ASSEMBLY
HINT:
Perform the inspection from the harness side with the connectors connected.
(a) Measure the voltage or resistance according to the value(s) in the table below.
Terminal No. (Symbol) | Terminal Description | Condition | Specified Condition |
---|---|---|---|
A-4 (IG) - Body ground | IG power supply | Engine switch on (IG) | 11 to 14 V |
A-3 (SW) - Body ground | Steering heater switch (Integration control&panel assembly) input signal | Engine switch on (IG), Steering heater switch (Integration control&panel assembly) pressed and held | 11 to 14 V |
A-2 (LED) - Body ground | LED output signal | Engine switch on (IG), Heated steering wheel system operating | Below 3 V |
A-1 (GND) - Body ground | Ground | Always | Below 1 Ω |
B-5 (SH1) - Body ground | Heater output signal | Engine switch on (IG), Heated steering wheel system operating | 11 to 14 V*1 |
B-3 (TH1) - Body ground | Thermistor input signal | Engine switch on (IG), Heated steering wheel system operating on at 0 to 40°C (32 to 104°F) | 2.5 to 4.8 V*2 |
B-2 (TH2) - Body ground | Thermistor ground | Engine switch on (IG), Heated steering wheel system operating | Below 1 V |
B-1 (SH2) - Body ground | Heater ground | Engine switch on (IG), Heated steering wheel system operating | Below 1 V |
HINT:
Lexus RX (RX 350L, RX450h) 2016-2024 Repair Manual > Pre-collision System: Diagnosis System
DIAGNOSIS SYSTEM FUNCTION OF WARNING INDICATOR AND MESSAGE (a) If the pre-collision system is not functioning properly, the driver is warned by the PCS warning light and a warning message is displayed on the multi-information display. *a PCS Warning Light PCS warning light Warning Mess ...
Lexus RX (RX 350L, RX450h) 2016-2024 Repair Manual > Air Conditioning System: Emission Gas NOx Sensor Circuit (B1461/61)
DESCRIPTION The smog ventilation sensor is installed to the front of the cooler condenser assembly to automatically control the air inlet mode (fresh, recirculation/fresh, and recirculation). This sensor detects NOx in the ambient air and transmits signals to the air conditioning amplifier assembly. ...