DESCRIPTION
When each button displayed on the multi-display assembly is selected via remote touch screen operation, the remote touch screen generates vibration feedback according to communication between the remote touch and radio receiver assembly.
CAUTION / NOTICE / HINT
NOTICE:
Depending on the parts that are replaced during vehicle inspection or maintenance, performing initialization, registration or calibration may be needed. Refer to Precaution for Audio and Visual System.
Click here
PROCEDURE
1. | CHECK MULTI-DISPLAY ASSEMBLY CUSTOMIZE SETTING |
(a) Using the multi-display assembly customize setting screen, check that the remote touch screen vibration feedback reaction force setting is not set to "Off".
OK:
The remote touch screen vibration feedback reaction force setting is not set to "Off".
NG | CUSTOMIZE SETTING |
|
2. | REMOTE TOUCH (REMOTE OPERATION CONTROLLER ASSEMBLY) SELF CHECK (CHECK VIBRATION FEEDBACK GENERATION CONDITION) |
(a) Enter self-diagnostic mode.
Click here
(b) Operate the remote touch screen laterally and check that the remote touch screen generates vibration feedback.
NOTICE:
Since the remote touch screen may recognize a pinch in/out or flick operation if operated with 2 fingers, always use 1 finger to operate the remote touch screen in self-diagnostic mode.
OK:
Remote touch screen generates vibration feedback.
OK | REPLACE RADIO RECEIVER ASSEMBLY |
NG | REPLACE REMOTE TOUCH (REMOTE OPERATION CONTROLLER ASSEMBLY) |
Lexus RX (RX 350L, RX450h) 2016-2025 Repair Manual > Headup Display System: Freeze Frame Data
FREEZE FRAME DATA FREEZE FRAME DATA (a) Whenever a meter DTC is detected, the headup display (meter mirror sub-assembly) stores the current vehicle state as freeze frame data. CHECK FREEZE FRAME DATA (a) Connect the Techstream to the DLC3. (b) Turn the engine switch on (IG). (c) Turn the Techstream ...
Lexus RX (RX 350L, RX450h) 2016-2025 Repair Manual > Sfi System: Evaporative Emission System Switching Valve Control Circuit Actuator Stuck Off (P24187F)
DTC SUMMARY DTC No. Detection Item DTC Detection Condition Trouble Area MIL Memory Note P24187F Evaporative Emission System Switching Valve Control Circuit Actuator Stuck Off Following condition met during key-off EVAP monitor:
EVAP pressure change when vent valve closed (o ...