INITIALIZATION
DESCRIPTION
(a) Zero point of the occupant classification sensors may deviate in the following situations. To ensure sensor accuracy, be sure to perform Zero Point Calibration.
HINT:
As the zero point is not automatically stored in a new occupant detection ECU, it is necessary to perform zero point calibration after replacing the occupant detection ECU.
HINT:
As the weight of accessories will be added to the weight of the occupant, the system will not be able to perform classification accurately.
HINT:
As the seat frame will warp slightly when the bolts that are used to install the front passenger seat are tightened, the load applied to the occupant classification sensor will change and the system will not be able to perform classification accurately.
HINT:
As the seat frame will warp slightly when the bolts that are used to install the front passenger seat are tightened, the load applied to the occupant classification sensor will change and the system will not be able to perform classification accurately.
HINT:
If any load or pressure is applied to the occupant classification sensors, the system will not be able to perform classification accurately.
HINT:
If the seat frame or vehicle floor has become deformed and additional pressure is applied to the occupant classification sensor, the system will not be able to perform classification accurately.
NOTICE:
Make sure that the front passenger seat is not occupied before performing the operation.
ZERO POINT CALIBRATION
(a) Zero point calibration procedure
(1) Check that all of the following conditions are met:
(2) Adjust the seat position according to the table below.
Adjustment Item | Position |
---|---|
Slide Direction | Rearmost position |
Headrest Height | Lowest position |
Front Tilt Height | Lowest position |
Seat Lifter Height | Lowest position |
Recline Angle | Upright position |
Leg Support* | Rearmost position |
(3) Turn the engine switch off.
(4) Connect the Techstream to the DLC3.
(5) Turn the engine switch on (IG).
(6) Turn the Techstream on.
(7) Enter the following menus: Body Electrical / Occupant Detection / Utility / Zero Point Calibration.
Body Electrical > Occupant Detection > Utility Tester Display |
---|
Zero Point Calibration |
(8) Perform zero point calibration by following the prompts on the Techstream screen.
OK:
"Zero Point Calibration is complete." is displayed.
HINT:
Lexus RX (RX 350L, RX450h) 2016-2024 Repair Manual > Theft Deterrent System: Security Horn Circuit
DESCRIPTION When the theft deterrent system is switched from the armed state to the alarm sounding state, the main body ECU (multiplex network body ECU) transmits a signal to cause the security horn assembly to sound at intervals of 0.4 seconds. WIRING DIAGRAM CAUTION / NOTICE / HINT NOTICE:
Bef ...
Lexus RX (RX 350L, RX450h) 2016-2024 Repair Manual > Solar Sensor: Inspection
INSPECTION PROCEDURE 1. INSPECT AUTOMATIC LIGHT CONTROL SENSOR (a) Disconnect the K3 automatic light control sensor connector. *a Front view of wire harness connector (to Automatic Light Control Sensor) (b) Measure the voltage and resistance according to the value(s) in th ...